Thông số kỹ thuật

  • Chế độ điều khiển: selectable among V/F control, General-purpose magnetic flux vector control, Optimum excitation control.
  • Tần số ngõ ra: 0.2 to 400 Hz
  • Torque khởi động( starting torque): 150% or more at 1 Hz, with General-purpose magnetic flux vector control and slip compensation.
  • Khả năng quá tải( overload current rating): 150% 60 s, 200% 0.5 s (inverse-time characteristics).
  • Chế độ bảo vệ: Overcurrent during acceleration, Overcurrent during constant speed, Overcurrent during deceleration, Overvoltage during acceleration, Overvoltage during constant speed, Overvoltage during deceleration, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay function), Heatsink overheat, Input phase loss∗3, Output side earth (ground) fault overcurrent at start, Output short circuit, Output phase loss, External thermal relay operation∗2, Parameter error, PU disconnection∗2, Retry count excess∗2, CPU fault, Inrush current limit circuit fault, 4 mA input fault∗2, Stall prevention stop, Output current detection value exceeded∗2, Inverter output fault∗5, Undervoltage.

Dải công suất điện áp

  • 3 pha 380 to 480 V, 50/60 Hz: 0.4kW-15kW
  • 1 pha 200 to 240 V, 50/60 Hz: 0.4kW-2.2kW

Ý nghĩa mã hàng

Ví dụ: FR-CS84-295-60

  • FR-CS8 là tên dòng biến tần, CS84 là loại ngõ vào 3 pha 380v-400v ngõ ra 3 pha 380v-400V, CS82S là loại có ngõ vào 1 pha 200v-220v ra 3 pha 200v-220v
  • 295 có nghĩa là ampe định mức là 29.5A
  • -60 là tiêu chuẩn mở rộng

Dịch vụ

  • Hỗ trợ kỹ thuật, hướng dẫn đấu nối, cài đặt thông số.
  • Chuẩn đoán lỗi, sửa chữa hư hỏng.

Tham khảo: Tài liệu đấu dây cài đặt mã lỗi biến tần mitsubishi CS80